Skip to content
Open in AI

KH-UCANFD-MAX-X4 ​

Four independent DB9 channels, desktop aluminum enclosure and push-button termination control for USB CAN / CAN FD

Available

Four independent connectors for desktop multi-bus debugging

Product Model

ChannelsModel / P/NHost interfaceCAN connectorsSales
4 channelsKH-UCANFD-MAX-X4USB4 × DB9 (independent channels)Contact sales
Hardware and Interfaces
  • Four CAN / CAN FD channels: independent CH1–CH4
  • Four independent DB9 connectors: one bus per connector, with the same pinout
  • Desktop enclosure: aluminum body, black end caps and white panels
  • Channel status: independent CAN1–CAN4 indicators
  • Termination status: independent RES1–RES4 indicators
Operation
  • Push-button control: side button cycles the four-channel termination combinations
  • Two SYS groups: SYS1 for CH1 / CH2, SYS2 for CH3 / CH4
  • Direct USB connection: approximately 0.8 m USB cable
  • Standard pinout: 2 = CAN_L, 3 = GND, 7 = CAN_H
  • Desktop applications: bus debugging, messaging, device integration and production testing

KH-UCANFD-MAX-X4 is a desktop USB-to-CAN / CAN FD interface that adds four independent CAN / CAN FD channels to a computer. It is designed for bus debugging, message transmission and reception, device integration, production testing and laboratory validation.

CH1–CH4 each connect to a target bus through an independent DB9 connector. All four connectors share the same pinout, simplifying test-harness preparation. The front panel groups SYS, CAN and RES indicators so that channel activity and termination settings can be checked directly.

The side button changes termination settings. RES1–RES4 correspond to CH1–CH4. An illuminated RES indicator means that channel's controllable termination resistor is enabled; an unlit indicator means it is disabled.

Product Highlights ​

1Four independent DB9 connectorsEach connector serves one CAN / CAN FD bus.
2Two system-status groupsSYS1 covers CH1 / CH2; SYS2 covers CH3 / CH4.
3Push-button terminationOne side button controls the four termination resistors.
4Central status displayCAN1–CAN4 and RES1–RES4 correspond to the four channels.
5Desktop aluminum enclosureSuitable for laboratories, test benches and fixed workstations.
6Direct USB connectionIncludes an approximately 0.8 m USB cable.

Applications ​

Multi-bus debuggingCAN messagingDevice integrationProduction testingLaboratory validation

Driving Intelligent Connections, Empowering the Future
蜀ICP备2023000218号-2