KH-UCANFD-PRO USB CAN / CAN FD Adapters ​

Product Overview ​

KH-UCANFD-PRO is the metal-enclosure USB CAN / CAN FD adapter family powered by CANmeleon. The current documented P/Ns are KH-UCANFD-PRO-X2U and KH-UCANFD-PRO-X4U, with two and four independent channels respectively.

Check the P/N on the unit for its channel count and DB9 pinout.

The PRO series has a metal enclosure, protective end caps and two DB9 connectors. Each X2U connector carries one channel; each X4U connector carries two channels.

Status: Available

ChannelsModel / P/NHost interfaceCAN connectorsPrice
2KH-UCANFD-PRO-X2UUSB-A2 × DB9, one channel per connector899 RMB
4KH-UCANFD-PRO-X4UUSB-A2 × DB9, two channels per connector1099 RMB

Series selection: Kunhong website USB CAN FD adapter series overview and model comparison

KH-UCANFD-PRO 45-degree view
KH-UCANFD-PRO front
KH-UCANFD-PRO DB9 side
KH-UCANFD-PRO button side
KH-UCANFD-PRO side

Typical Applications ​

  • Synchronized acquisition, diagnosis and replay on multiple CAN FD buses
  • Vehicle and controller debugging, including BMS, VCU and chassis networks
  • Robot and industrial-network debugging
  • High-load CAN FD acquisition and stress tests
  • Automated test benches, production validation and long-term recording

Multi-Firmware Support ​

The following firmware is supported on KH-UCANFD-PRO-X2U and KH-UCANFD-PRO-X4U.

Use CANmeleon Device Manager to check the firmware available for your model and license. See each firmware page for supported modes, channel counts and driver requirements.

Specifications ​

ItemSpecification
ChannelsX2U: 2; X4U: 4
Host interfaceUSB 2.0 High-Speed, up to 480 Mbit/s, USB-A
CAN connectorsTwo DB9 connectors. X2U: one channel per connector. X4U: two channels per connector.
CAN protocolsCAN 2.0A/B, ISO and Non-ISO CAN FD
Arbitration rate25 kbit/s to 1 Mbit/s
Data-phase rate25 kbit/s to 12 Mbit/s
Channel operationAll channels can operate at high load simultaneously
Payload and identifiersCAN FD payload up to 64 bytes; 11-bit standard and 29-bit extended IDs
TimestampHardware timestamp, approximately 1 μs resolution
MonitoringBus load, error frames and channel state
Electrical isolation3000 V on both X2U and X4U
EnclosureMetal enclosure with protective end caps
DimensionsApproximately 124 × 84 × 24 mm; USB cable approximately 800 mm
Operating temperature−40 to +85 °C
ESDIEC 61000-4-2: ±15 kV air discharge, ±8 kV contact discharge
TerminationButton-controlled 120 Ω nominal termination, with separate RES indication for each channel
PowerUSB bus power
Operating systemsWindows, Linux and macOS
APIsC/C++, C#, Python, SocketCAN and python-can
FirmwareMulti-firmware support

ISO and Non-ISO CAN FD ​

ISO CAN FD and the earlier Non-ISO CAN FD format are not fully compatible. X2U and X4U support both modes; the adapter, target nodes and host software must use matching modes, rates and sample points.

CAN FD supports classical CAN 2.0A/B communication, but CAN FD extensions cannot be used on a classical CAN network.

Dimensions ​

KH-UCANFD-PRO dimensional drawing: 124 × 84 × 24 mm, USB cable approximately 800 mm
Enclosure: approximately 124 × 84 × 24 mm; USB cable: approximately 800 mm.

DB9 Pinout ​

Both models have two DB9 connectors. DB9-1 carries CAN1 and, on X4U, CAN3. DB9-2 carries CAN2 and, on X4U, CAN4.

PRO-X2U / X4U pinout: DB9-1 carries CAN1 / CAN3 and DB9-2 carries CAN2 / CAN4
Two DB9 connectors; the additional CAN3 / CAN4 channels apply to X4U.
PinDB9-1DB9-2X2U / X4U usage
1CAN3_LCAN4_LAdditional-channel Low, X4U only
2CAN1_LCAN2_LMain-channel Low, both models
3GNDGNDSignal ground
4CAN3_L (OPT)CAN4_L (OPT)Optional parallel Low pin for the additional channel, X4U only
5GNDGNDSignal ground
6GNDGNDSignal ground
7CAN1_HCAN2_HMain-channel High, both models
8CAN3_HCAN4_HAdditional-channel High, X4U only
9——Undefined; do not connect

X2U uses pins 2 (CAN_L), 7 (CAN_H) and any GND pin on each connector. X4U adds the second channel on pins 1 (CAN_L), 8 (CAN_H) and any GND pin; pin 4 is an optional parallel CAN_L connection for that additional channel. Use a matching terminal adapter or harness to avoid mixing the two pin assignments.

User Button and Termination ​

A short press of the user button switches the controllable 120 Ω termination resistors. A lit RES indicator means termination is enabled for its channel; an unlit RES indicator means it is disabled. X2U uses RES1 / RES2, while X4U uses RES1 through RES4.

KH-UCANFD-PRO user button and termination indicators
Use the user button to switch termination and the corresponding RES indicator to confirm its state.

Note: While software, including CANmeleon device manager, is using the device, the button is disabled to prevent accidental activation.

Enable termination only when the corresponding adapter channel is at an end of its CAN bus. Each bus should have one 120 Ω termination at each end.

Indicator LEDs ​

IndicatorMeaning
SYSNormal operation: steady on with CANmeleon firmware 8.15.2 or earlier, blinking with later versions; slow blink in Boot mode; fast blink during upgrade
CAN1–CAN4Yellow: channel closed; cyan: normal TX/RX; green: receive only; red: Bus-Off. X2U uses CAN1 / CAN2
RES1–RES4Lit: corresponding termination enabled; unlit: disabled. X2U uses RES1 / RES2

See Second-Generation LED Indications for the complete state reference.

Resources ​

Getting Started ​

Preparation ​

Prepare the host computer, target CAN / CAN FD network and DB9 test harness. On X4U, each DB9 carries two channels, so use a matching terminal adapter or one-to-two DB9 Y cable. Confirm CAN / CAN FD mode and network timing before connecting.

  • Install CANmeleon device manager on Windows or the KH-UCANFD Linux SDK on Linux.
  • Enable a channel's termination only if it is at the corresponding bus end.

1. Connect the Hardware ​

  1. Connect USB and wait for device recognition. Keep USB connected during communication and firmware updates.
  2. On X2U, connect the two DB9 connectors to CAN1 and CAN2 using main-channel pins 2 / 7. On X4U, DB9-1 carries CAN1 / CAN3 and DB9-2 carries CAN2 / CAN4; main channels use pins 2 / 7, additional channels use pins 1 / 8, and pin 4 is the optional parallel Low pin. Ground is available on pins 3 / 5 / 6.
  3. Check CAN_H / CAN_L polarity before powering the network. Retain one 120 Ω termination at each end of each bus.

2. Select or Switch Firmware ​

Check that the X2U shows two channels or the X4U shows four. Follow the CANmeleon firmware management guide to select and switch firmware. Wait for USB recognition before opening the host software.

3. Configure Termination ​

  1. Short-press the user button to switch the built-in termination.
  2. Confirm the state using the corresponding RES indicator.
  3. Enable termination only on the channels at a bus end.

4. Start Communication ​

  1. Validate CAN1 before enabling the remaining channels.
  2. Match CAN / CAN FD mode, ISO / Non-ISO mode, arbitration rate, data rate and sample points to the target network.
  3. Send or receive a known frame before starting multichannel or high-load tests.

Troubleshooting ​

  • Device not detected: try another USB port and inspect the device in CANmeleon device manager.
  • Device detected but no frames: check the DB9 pinout, ground, bit rate, CAN FD mode and termination.
  • Error frames or Bus-Off: stop transmission and check for shorts, reversed wiring, duplicate termination or mismatched timing.
  • Software does not detect the device after firmware switching: wait for USB re-enumeration, then reopen the host software.
GuideCoverage
CANmeleon device manager User GuideInstallation, device discovery and firmware management
SocketCAN Basic Debuggingcandump, cansend and troubleshooting
python-canPython messaging and automation
Linux SDK InstallationSDK installation and setup
Second-Generation LED IndicationsSYS, CAN and RES indicators

Driving Intelligent Connections, Empowering the Future